What was found
INSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.2" X 1.5" AT BS 1351 TO 1480 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.2" X 1.5" AT BS 1351 TO 1480 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.