What was found
INSPECTION TYPE:C, MCD FLOOR PANEL FOUND 2 PUNCTURE HOLE 1.2" X 1.5" AND 1.2" X 1.8" AT BS 1480 TO 1598 RBL 33" TO RBL 55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MCD FLOOR PANEL FOUND 2 PUNCTURE HOLE 1.2" X 1.5" AND 1.2" X 1.8" AT BS 1480 TO 1598 RBL 33" TO RBL 55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.