What was found
INSPECTION TYPE:C, MCD STA 972 TO 1112, LBL 11 TO RBL 11, FLOOR PANEL FOUND 3 PUNCTURE HOLES AND TOGETHER WITH 6 DENT MARKS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MCD STA 972 TO 1112, LBL 11 TO RBL 11, FLOOR PANEL FOUND 3 PUNCTURE HOLES AND TOGETHER WITH 6 DENT MARKS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.