What was found
INSPECTION TYPE:C, LT WING - INBD MAIN FLAP INBD HINGE FTG FOUND CRACK. LT WING INBD MAIN FLAP INBD HINGE FITTING, REPAIRED IAW SRM 57-53-02-2R1, FIG 201, ORG MATL 7075-T73 FORGING, CRK LENGTH AT INBD FLANGE IS 1.5" AND OTBD FLANGE IS 0.875" DAMAGE CUTOUT IS 1.5" X 0.75" (2 LOCATION). THIS IS CLASSIFIED AS A MAJOR REPAIR WITH AND 10134-2007-7075T6511 AS REPAIR ANGLE AND 7075T651-0313IN AS REPAIR FILLER REPAIR SIZE 2"X4".