What was found
INSPECTION TYPE:C, MCD STA 930 TO 977, LBL 11 TO RBL 11 FLOOR PANEL FOUND 1 CRACK (5" LONG) & 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MCD STA 930 TO 977, LBL 11 TO RBL 11 FLOOR PANEL FOUND 1 CRACK (5" LONG) & 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.