What was found
INSPECTION TYPE:C, SURVEY SEQ NR580-F1-11, FUSELAGE SKIN AT BETWEEN BS1697 TO BS 1723 AND STR 44R-47R EXISTING REPAIR DOES NOT CORRELATE TO EFN 58020071001. SKIN REPAIRED IAW RS R53-00-36836 & EO B747-5330-4005-A. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR. ORG MATL CLAD PLATE 2024T351- 0.071" AT TRIMMED OUT AREA OF 0.250" THK MACHINED SKIN. DAMAGE OF DENT WITH CUTOUT SIZE 2.9" X 6.5" FINAL CUTOUT AT OVERLAPPING SKIN 20.5" X 14.6250", OVERLAPPING SKIN 13.2500" X 2.7500".REPAIR SIZE 33.125" X 24.5"