What was found
INSPECTION TYPE:2C, REPAIR SURVEY SEQUENCE NR 290-F1-06, BETWEEN STA 1959 AND 1975, L40L AND L45L SRM 53-50-00, FIG. 16, VOL 1, REV 38 REQUIRES INNER DOUBLER TO BE .068 AND OUTER TO BE .080, ACTUAL INNER DOUBLER IS .080 AND OUTER DOUBER IS .100. REMOVED DOUBLER AND INNER DOUBLER, REMOVED DAMAGE, FABRICATED AND INSTALLED NEW REPAIR DOUBLERS AND FILLERS IAW SRM 53-00-15 REPAIR 8, FIG. 202