What was found
INSPECTION TYPE:1C, REPAIR SURVEY SEQ NR 282-F1-06 BETWEEN STA 824-840 L41L-L43L. REPAIR NOT CORRELATED WITH SRM 53-00-01 REP.8, FIG 201, SHEET 6 WRONG DOUBLER MATERIAL, WRONG THICKNESS, WRONG PITCH, AND IS LOCATED IN RVSM AREA IAW SRM 53-01-00. GAINED ACCESS TO REPAIR AREA, REMOVED EXISTING REPAIR, FABRICATED & INSTALLED NEW REPAIR REF STASA EA 011-5330-01-A2179 AND EO MD11- 5330-36748-A. RESTORED AREA.