What was found
INSPECTION TYPE:4C, FOUND CORROSION ON FLOOR PANEL FWD OF RCB, LBL7.5. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STA SA EA NR011-5321-01-A2352, REV IR AND UPS EO MD11-5310-38041-A, RESTORED AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:4C, FOUND CORROSION ON FLOOR PANEL FWD OF RCB, LBL7.5. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STA SA EA NR011-5321-01-A2352, REV IR AND UPS EO MD11-5310-38041-A, RESTORED AREA.