What was found
INSPECTION TYPE:1C, RT WING FIXED L/E OTBD OF SLAT TRACK DOOR NR1 CUT OUT. FOUND REPAIR DOUBLER CRACKED. REMOVED EXISTING REPAIR DOUBLER AT RT WING L/E OTBD OF SLAT TRACK DOOR NR 1 CUT OUT AREA. FABRICATED AND INSTALLED REPAIR DOUBLER REF SRM 5 7-40-02-2, R7, FIG 207, SHT 2 AND 3, REV 44.