What was found
RIGHT GEAR DOOR WOULD NOT CLOSE AFTER TAKEOFF. FOLLOWED ECAM PROCEDURE A AND QRH PROCEDURE. RETURNED TO DEPARTURE, GEAR EXTENDED NORMAL UPON THE RETURN. DEFERRED IAW 32-30-01. R & R RT MLG DOOR UPLOCK ASSY IAW MM 32-31-33-04. PERFORMED A GEAR SWING TO VERIFY NORMAL GEAR INDICATION. NO DEFECTS NOTED IAW MM 07-11-00-00. THIS CLEARS M462809. PLACARD REMOVED, DMP REVERSED.