What was found
INSPECTION TYPE:C1, AFTER REMOVING ANTI-SKID FOUND FLOOR PANEL BS 440 TO 480 LBL25 TO LBL45 TO HAVE CRUSHED HONEY COMB CORE ON FWD END IN 2 AREAS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G AND SRM 53-00-50-1A-1, FIG 101.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, AFTER REMOVING ANTI-SKID FOUND FLOOR PANEL BS 440 TO 480 LBL25 TO LBL45 TO HAVE CRUSHED HONEY COMB CORE ON FWD END IN 2 AREAS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G AND SRM 53-00-50-1A-1, FIG 101.