What was found
INSPECTION TYPE:C2, FLOOR SUPPORT UPPER PLATE IS PUNCTURED, BS 900, WL 208, LBL 3 TO LBL 20. SUPPORT UPPER PLATE HAS NO LIMITS REPAIRABLE BY REPLACEMENT; REMOVED PUNCTURED; FABRICATED REPLACEMENT AND INSTALLED IAW SRM 51-10-02-0G, SRM 51-40-05-0G, SRM 51-40-06-0G AND SRM 51-20-0G.