What was found
INSPECTION TYPE:C1, CABIN FLOOR SHEAR WEB AT BODY STA 1700+3 AND LBL 41, WEB IS CORRODED. REMOVED CORROSION, ORIGINAL THICKNESS .071, LOSS OF .010 WITH .061 MATERIAL LOSS IS OUT OF LIMITS IAW SRM 53-00-51-1A1. ACCOMPLISHED EA 1104 54/ EO B757-5310-42643-A FOR EXTENDED MATERIAL LOSS.