What was found
INSPECTION TYPE:C3, AFT PIT STA 1580 FRAME IS DENTED BETWEEN STR 21R AND 22R. REMOVED DAMAGE AND REPAIRED FRAME SECTION IAW EA 110396.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3, AFT PIT STA 1580 FRAME IS DENTED BETWEEN STR 21R AND 22R. REMOVED DAMAGE AND REPAIRED FRAME SECTION IAW EA 110396.