What was found
INSPECTION TYPE:MOD WHILE WORKING NR 7 L/E SLAT FUNCTIONALS FOUND BULB SEAL RETAINER ON THE SLAT COVE CRACKED, OTBD END, REMOVED RETAINER, FABRICATED REPLACEMENT, AND INSTALLED RETAINER IAW DWG 114N4046, SRM 51-40-05-0G, AND SOPM 20-50-01.