What was found
INSPECTION TYPE: C1, CORROSION ON MAIN CARGO STUB BEAM UPPER SURFACE AT NUTPLATE LOCATIONS, BS 900, RBL 48-54, WL 208. REPLACED IAW DWG 144N1079, AND FABRICATED IAW DWG 144N1074. INSTALLED IAW SRM 51-40-02, SRN 51-40-05, AND SRM 51-40-08.