What was found
INSPECTION TYPE:C-CHECK, LOWER AFT CARGO COMPARTMENT FLOOR STRUCTURE RT SIDE BS 1280 ZEE ANGLE CORRODED AROUND TIE DOWN FITTING. REMOVED CORROSION AND RESTORED FINISH IAW EA 111454 IR AND EO B757-531 0-44856-A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C-CHECK, LOWER AFT CARGO COMPARTMENT FLOOR STRUCTURE RT SIDE BS 1280 ZEE ANGLE CORRODED AROUND TIE DOWN FITTING. REMOVED CORROSION AND RESTORED FINISH IAW EA 111454 IR AND EO B757-531 0-44856-A.