What was found
INSPECTION TYPE:C, FLOOR PANEL FOUND 5EA PUNCTURES AND CRACK AT MIDDLE TOGETHER WITH DENT RUNNING THROUGH AT STA 933 TO STA 985, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, FLOOR PANEL FOUND 5EA PUNCTURES AND CRACK AT MIDDLE TOGETHER WITH DENT RUNNING THROUGH AT STA 933 TO STA 985, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-01.