What was found
INSPECTION TYPE:C, FLOOR PANEL FOUND 11EA PUNCTURES TOGETHER WITH DENT RUNNING THROUGH AT STA 985 TO STA 1090, LB 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, FLOOR PANEL FOUND 11EA PUNCTURES TOGETHER WITH DENT RUNNING THROUGH AT STA 985 TO STA 1090, LB 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-01.