What was found
INSPECTION TYPE:C, MAIN EQUIPMENT CTR STA 246, LBL 40" VERTICAL STIFFENER FOUND CRACKED. (CRACK 1.1" LENGTH) STIFFENER REPAIRED IAW SRM 53-10-51-2R4, FIG 201, REV 49 ORI. MATERIAL BAC1490-2793-7075T62,THIS IS MAJOR REPAIR WITH MATERIAL 7075T6-0063" AS STIFFENER, CLAD7075T6-0080" AS REPAIR DOUBLER & BAC1512-3347- 7075T6511 AS REPAIR FILLER, REPEAT INSP. AT 3000 FLT CYC. OR 24 MONTHS WHICH EVER OCCURS FIRST IS REQ REPAIR LENGTH IS 14.6"