What was found
INSPECTION TYPE:C, CENTER CARGO BS 1657 -1685 LONGERON 48L CORRODED. CORROSION REMOVED & FOUND EXCEED LIMITS IAW SRM 53-00-00, FIG 205. CORROSION TRIMMED OUT IAW EN:1345-11, SHEET 1,STEP 2. HFEC INSPECTION CARRIED OUT & NO CRACK EVIDENT. NEW LONGERON & CHANNEL FABRICATED IAW EN:1345-11, STEP 6 & 7 AND INSTALLED IAW SRM 51-33-01, REV 47.