INSPECTION TYPE:C, MLG WW - LT SIDE PANEL AT APPROX BS 1294 CUT-OUT DOUBLER FOR AILERON INPUT RODS, FOUND CRACKED AT FWD SIDE. HFEC INSPECTION CARRIED OUT, CRACK IS APPROXIMATELY 1INCHE IN LENGTH. CRACKED DOUBLER REMOVED IAW SRM 51-31-01. NEW DOUBLER DRILLED IAW DWG AE A0526. NEW DOUBLER INSTALLED IAW SRM 51-33-01, REV 47 AND DWG AEA0526.