What was found
INSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR STRUCTURE SEAT TRACK AT STA 897, LBL 60 HAS LIGHT CORROSION AROUND FLOOR PANEL FASTENER. REMOVED CORROSION ON MAIN CARGO COMPARTMENT FLOOR STRUCTURE SEAT TRACK AT STA 897, LBL 60 ORIGINAL MATERIAL THICKNESS .070. REMOVED .016 WITH .054 REMAINING IS OUT OF LIMITS IAW SRM 53-00-52-1A1. VERIFIED MEASUREMENT FOR MATERIAL LOSS PLUGGED NUT PLATE HOLES AND RELOCATED NUT PLATE, FABRICATED NEW FLOOR PANEL IAW EA 120042 EO B757-5310-45667-A.