What was found
INSPECTION TYPE:C-CK FWD PIT STA 800 STR 24L VERTICAL FRAME IS DENTED. REMOVED DAMAGE FROM FWD PIT STA 800, STR 24L VERTICAL FRAME, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-972R, DETAIL 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.