What was found
INSPECTION TYPE:C-CK, FWD CARGO PIT STA 800, STR 24L VERTICAL FRAME IS DENTED. CUT OUT DAMAGE AND REPAIRED FRAME AT STA 800, STR 24L BY INSTALLING REPAIR DOUBLER FABRICATED FROM 7075-T6-.080 IAW SRM 53-00-07-2R5 DETAIL 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C-CK, FWD CARGO PIT STA 800, STR 24L VERTICAL FRAME IS DENTED. CUT OUT DAMAGE AND REPAIRED FRAME AT STA 800, STR 24L BY INSTALLING REPAIR DOUBLER FABRICATED FROM 7075-T6-.080 IAW SRM 53-00-07-2R5 DETAIL 3.