What was found
INSPECTION TYPE: C, MAIN CARGO BAY, BS 1180 BETWEEN STRINGER 15L AND 16L, FRAME FREE FLANGE IS GOUGED. REMOVED DAMAGE, ORIGINAL THICKNESS .375 WITH A LOSS OF .045 AND .330. OUT OF LIMITS IAW SRM 53-40-08-1A3. ACCOMPLISHED EA 120250, EO B757-5310-46174-A.