What was found
INSPECTION TYPE:C, MAIN DECK CARGO COMPARTMENT FLOOR PANEL ASSY UPPER SKIN AND CORE DAMGE ABOUT 0.4"X0.4"X0.0975" AT STA 1509, RBL6.5 CUT OUT THE UPPER SKIN AND CORE WITH 0.5" DIAMETER. REPAIR IAW REV:52, SRM 53-00-50, REPAIR GENERAL FIGURE 201,PARA.4.C.