What was found
INSPECTION TYPE:C, MAIN DECK CARGO COMPARTMENT FLOOR PANEL ASSY UPPER SKIN AND CORE DAMAGE ABOUT 0.4" X 0.4"X 0.0625" AT STA 1368,RBL 1 AND 1.9"X1.4"X0.06" AT STA 1375 RBL 4 CUT OUT THE UPPER SKIN AND CORE WITH 0.5" DIAMETER AT STA 1368,RBL 1 AND 2" DIAMETER AT STA 1375,RBL 4. REPAIR IAW REV:52 SRM 53-00-50 REPAIR GENERAL FIGURE 201 PARA.4.C. AND 4.D.