What was found
INSPECTION TYPE:C, MAIN DECK CARGO COMPARTMENT FLOOR PANEL ASSY UPPER SKIN AND CORE DAMAGE ABOUT 0.5" X 0.5"X 0.1" AT STA 1387, RBL 84 AND 0.4" X 0.4" X 0.1" AT STA 1389 RBL 84 CUT OUT THE UPPER SKIN AND CORE WITH 0.5" DIAMETER AT STA 1387, RBL 84 AND 0.4" DIAMETER AT STA 1389, RBL 84. REPAIR IAW REV:52 SRM 53-00 -50 REPAIR GENERAL FIGURE 201 PARA 4.C.