What was found
INSPECTION TYPE:C, MAIN DECK CARGO COMPARTMENT FLOOR PANEL ASSY UPPER SKIN AND CORE DAMAGE ABOUT 0.5" X 1.0" X 0.1" AT STA 1518, RBL 66 CUT OUT THE UPPER SKIN AND CORE WITH 1.1" DIAMETER AT STA 1518, RBL 66. REPAIR IAW REV:52 SRM 53-00-50, REPAIR GENERAL FIGURE 201, PARA 4.D.