What was found
INSPECTION TYPE:C, MAIN DECK CARGO COMPARTMENT FLOOR PANEL ASSY UPPER SKIN AND CORE DAMAGE ABOUT 2.5" X 2.5" X 0.030" AT STA 1001, LBL 31 CUT OUT THE UPPER SKIN AND CORE WITH DIMENSION LXW=2.7" X 2.5". REPAIR IAW REV: 52, SRM 53-00-50, REPAIR GENERAL FIG 201, PARA 4 D