What was found
INSPECTION TYPE:C, MAIN DECK CARGO COMPARTMENT FLOOR PANEL ASSY UPPER SKIN AND CORE DAMAGE ABOUT 2.0" X 1.0" X 0.040" AT STA 906, LBL 86 CUT OUT THE UPPER SKIN AND CORE WITH DIMENSION LXW=1.5"2.1".REPAIR IAW REV:52 SRM 53-00-50, REPAIR GENERAL FIGURE 201, PARA 4D.