INSPECTION TYPE:4C, R3 DOOR BS 1305 AFT JAMB LOWER LIGHTNING HOLE CRACKED IN CORNER. REPAIRED R-3 AFT DOOR JAMB LOWER LIGHTNING HOLE AT STA 1305 REF SRM 53-40-15, REPAIR 3, FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:4C, R3 DOOR BS 1305 AFT JAMB LOWER LIGHTNING HOLE CRACKED IN CORNER. REPAIRED R-3 AFT DOOR JAMB LOWER LIGHTNING HOLE AT STA 1305 REF SRM 53-40-15, REPAIR 3, FIG 201.