What was found
INSPECTION TYPE:4C, SPLICE FITTING IS CRACKED IN CENTER CARGO STA 5-123 AND L-34R. FABRICATED AND REPLACED SPLICE FITTING AT STA 5-123 AND L-34R IAW DWG A5A7112 AND SRM 51-33-01, PG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:4C, SPLICE FITTING IS CRACKED IN CENTER CARGO STA 5-123 AND L-34R. FABRICATED AND REPLACED SPLICE FITTING AT STA 5-123 AND L-34R IAW DWG A5A7112 AND SRM 51-33-01, PG 1.