What was found
EMERGENCY LIGHTS TEST FAIL AND EMERGENCY BATTERY LOW MESSAGE DISPLAYED ON PRE-FLT. RESTORED DMP 33-50-4, LET BATTERY CHARGE, PERFORMED ADJ/TEST OF EMER LT SYS IAW MM 33-51-01-700-802. OPS CK GOOD. THIS CLEARS M501952.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS TEST FAIL AND EMERGENCY BATTERY LOW MESSAGE DISPLAYED ON PRE-FLT. RESTORED DMP 33-50-4, LET BATTERY CHARGE, PERFORMED ADJ/TEST OF EMER LT SYS IAW MM 33-51-01-700-802. OPS CK GOOD. THIS CLEARS M501952.