What was found
INSPECTION TYPE:C4, 3 OPEN FASTENER HOLES DRILLED INTO RADIUS OF FLOOR SUPPORT IN THE AFT CARGO BAY, BETWEEN BS 1293 AND 1298, RBL 16, WL 156. R & R STRINGER IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C4, 3 OPEN FASTENER HOLES DRILLED INTO RADIUS OF FLOOR SUPPORT IN THE AFT CARGO BAY, BETWEEN BS 1293 AND 1298, RBL 16, WL 156. R & R STRINGER IAW SRM 51-40-02.