What was found
INSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT BS 660 BETWEEN STRINGER 24R AND 25R, IS DENTED ON INBD FREE FLANGE CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLES SHEER TIE AND STRINGER CLIPS IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110434 IR