What was found
INSPECTION TYPE:C1, FLOOR PANEL BS 1200 TO BS 1320, RBL 45.5 TO RBL 60, WL 208 HAS EDGE DAMAGE AND IS CRACKED ON LWR SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, AMM 53-01-01-4, AND UPS EO B757-5320-9692-G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, FLOOR PANEL BS 1200 TO BS 1320, RBL 45.5 TO RBL 60, WL 208 HAS EDGE DAMAGE AND IS CRACKED ON LWR SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, AMM 53-01-01-4, AND UPS EO B757-5320-9692-G.