What was found
INSPECTION TYPE:C-CHECK, MAIN CARGO HAS CORROSION ON SHEAR WEB UPPER SURFACE BS 470, LBL 56. REMOVED CORROSION ORIGINAL THICKNESS .063 LOSS,.002 REMAINING .061 THERE IS NO SRM LIMITS FOR THIS AREA PERFORMED REQUIRED INSPECTIONS, TREATED, PRIMED, PAINTED AND CIC'D AREA IAW EA 111091 EO B757- 5310-44145-A, STA 470, LBL56 AT MAIN CARGO DOOR FLOOR WEB.