What was found
INSPECTION TYPE:C-CK, MAIN CARGO AREA; TOOLING DAMAGE ON SEAT TRACK STA 1020+16 LBL 45. REMOVED DAMAGE AT STA 1020+16 LBL 45 ORIGINAL MATERIAL THICKNESS .092 LOSS .013 WITH .079 REMAINING IS OUT OF LIMITS IAW SRM 53-00-51-1A1 VERIFIED LIMITS, PERFORMED INSP STEPS, ROTO PEENED AREA TREATED PRIMED IAW EA 111117 IR, EO B757-5310-44199-A.