What was found
CLIMBING THROUGH 11,000 FT, "CREW ENTRY DOOR" MESSAGE ILLUMINATED. QRH PROCEDURE FOLLOWED. PRESSURIZATION APPEARED NORMAL. RETURNED FOR INSPECTION. R & R CREW ENTRY DOOR PROXIMITY SENSOR IAW WDM 52-71-31, PG 5, SHEET 1. OPS CHECKED GOOD.