What was found
INSPECTION TYPE:C, FX BS 955 RT T-FITTING FOUND CORROSION FROM 6 TO 10 O/C POSITION. T-FITTING REPLACED & INSTALLED IAW SRM 51-10-02, REV 49 & EO B767-5350-17922-H APPENDIX 'D' ORG MAT'L BAC1505-100900-7075T73511 CORROSION JUST AROUND FASTENER HOLE. A NEW FITTING REPLACEMENT MUST BE INSTALLED IAW EO B767-5350-17922-H, APPENDIX D.