INSPECTION TYPE:C, FLOOR PANEL FOUND SEVERAL DENTS AND PUNCTURES AT STA 930 TO 975 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693H AND INSTALLED IAW AMM 53-01-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, FLOOR PANEL FOUND SEVERAL DENTS AND PUNCTURES AT STA 930 TO 975 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693H AND INSTALLED IAW AMM 53-01-06.