What was found
INSPECTION TYPE:C, FUSE LT BS 955 B REAR SPAR FITTING AREA 2EA CRACKS FOUND AT FAIL SAFE STRAP AT 3 O'CLOCK POSITION THROUGH THICKNESS AND 9 O'CLOCK POSITION APPROX. .1250" FUSE LT SIDE BS 955 REAR SPAR B/H FITTING FAIL SAFE STRAP REPAIRED AS IAW EO B767-5350-17922-I APP C, ORG MAT'L IS 2024T351-0750" MACHINED STRAP, CRACK AT 3 O/C POSITION THROUGH THICKNESS & 9 O/C POSITION APPROX .1250" FINAL CUTOUT SIZE 7.75" X 2" THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR