What was found
INSPECTION TYPE:ETOP, AUTO CABIN PRESS CONT SYS NR 2 (1 SYS INOP) REF TO WAN NR 1785042 AND DMI 458926. REF TO FIM 21-31-00 PERFORMED CABIN PRESS CONTROLLER BITE ON SYS NR2 FOUND SYS IS OK ALSO OPS CK OF OUTFLOW VALVE IAW AMM 21-31-00-5 SATIS NI O MORE MSG AT EICAS. DEFERRAL CLOSED AND PLACARD REMOVED.