What was found
INSPECTION TYPE:8C, MCD FLOOR PANEL FOUND 8 DENTS AND 7 PUNCTURES AT STA 1197+22 TO STA 1207 LBL11 TO RBL11. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:8C, MCD FLOOR PANEL FOUND 8 DENTS AND 7 PUNCTURES AT STA 1197+22 TO STA 1207 LBL11 TO RBL11. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM53-01-01.