What was found
INSPECTION TYPE:8C, M/DECK STA 998, RBL 10 FLOOR SUPPORT LOWER FACE FOUND CRACKED. M/DECK STA 998, LBL10 TO RBL10 AREA FLOOR SUPPORT REPLACED AND INSTALLED IAW HX RS NR R-53-50-37193 REV A AND EO NR B767-5310-43780-A. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR, ORIGINAL MATERIAL IS BAC1518-790-7075T6511, CRACK AREA AT RBL10 AREA THROUGH THE WHOLE HOLE EDGE, SUPPORT WHOLE LENGTH IS 20.9375".