INSPECTION TYPE:7C, MCD FLOOR PANEL FOUND 12 DENTS AND 5 PUNCTURES AT BS 283 TO 412 , LBL 11 TO RBL 11. NEW FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-H AND INSTALLED AS PER AMM 53-01-06.