What was found
INSPECTION TYPE:C, CABIN R2 DOOR FWD CUTOUT WEB CRACKED BETWEEN S24R AND S25R. R2 DR FWD CUTOUT FRAME WEB REPAIRED IAW SRM 53-60-15-2R4, FIG 201. JUST AT STA 800 BTN S22R & S26R, CRACK LENGTH 0.875", 0.25" DIA STOP HOLE DRILLED, THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATL 2024T3- 0050" AS REPAIR INNER & OUTER DOUBLER, REPAIR SIZE 5.5" X 19". REPEAT INSP IAW SRM 53-60-15-2R4, REPAIR 4, FIG 201, SHT 13, TABLE 2.